Medi-Stim, Inc.
217 Industrial Court
Wabasha, MN 55981
Toll Free: 1-800-363-STIM
Ph: (651) 565-2400
Fax: (651) 565-2410
sales@medi-stim.com
|
View other Combination Units |
|
IF/TENS/EMS/Russian |
- Four channel (8-lead) all digital combo Muscle Stim, Russian Stim, Interferential, and TENS
- Separate intensity controls for each channel
- Fully adjustable EMS mode (Synchronous) with programmed default settings
- Fully adjustable Russian Stim mode with programmed default settings
- 3 Preset Interferential programs and 1 adjustable frequency program with vector sweep
- 2 fully adjustable TENS modes (Normal and Modulated Width) Burst Mode is preset.
- One program can be locked for each EMS, Interferential, and TENS modes
- Treatment start/pause button
- Easy to use and operate
- Treatment timer (1-60 minutes)
- Compliance monitor
- LCD display with push button control panel
- Safety power on/off switch
- Heavy duty color-coded cables
- Durable for clinic or home setting
- 1 year warranty
- Available in 2 channel version: AllStim2
- Comes with 2 pkgs of 4 reusable self-adhering electrodes, 2 pairs of 48” 4-lead pin connection wires, 4 AA high-powered Ni-MH rechargeable batteries, 1 each AA battery charger, 4 AA alkaline batteries, AC wall adapter, zippered padded carrying fanny pack, and instruction manual
- Leadwire reorder #LWALLBR, #LWALLGY
- Channel:(4) Four
- Timer: 1 - 60 minutes with buzzer sound at the end of treatment time
- Compliance Number: Counts the number of times the start/stop key is pressed
- Compliance Timer:Counts the units of total treatment time unit was used. (1 unit = 5 minutes)
- Lock Key: Saves the selected treatment parameters and locks out any other input
- Power Supply: AC wall adapter or 4 AA batteries
- Size: 10 x 15.8 x 4.45 cm
- Weight: 408 grams, unit only
- Conventional Stim (MS-CONVL) [Default EMS mode]
- Amplitude 90 mA peak at 500 ohm load (±10%)
- Output Voltage 45 V peak to peak at 500 ohm load (±10%)
- Waveform Symmetrical biphasic
- Pulse Rate 1 - 150 Hz [Default 70 Hz]
- Pulse Width 200 - 450 µS [Default 400 ms]
- Contraction Time 1 - 60 seconds (+/- 2 sec / 10 sec) [Default 10 sec.]
- Relaxation Time 0 - 60 seconds (+/- 2 sec / 10 sec) [Default 15 sec.]
- Ramp Up/Down 1 - 9 seconds (+/- 2 sec / 10 sec) [Default 2 sec.]
- Amplitude 90 mA peak at 500 ohm load (±10%)
- Output Voltage 45 Volts peak to peak at 500 ohm load (±10%)
- Waveform Symmetrical biphasic
- Pulse Rate Channels 1 & 3 fixed at 2500 Hz; Channels 2 & 4 fixed at 2550 Hz
- Pulse Width 200 µS fixed
- Contraction Time 1 - 60 seconds (+/- 2 sec / 10 sec) [Default 10 sec.]
- Relaxation Time 0 - 60 seconds (+/- 2 sec / 10 sec) [Default 15 sec.]
- Ramp Up/Down 1 - 9 seconds (+/- 2 sec / 10 sec) [Default 2 sec.]
- Amplitude 80 mA peak at 500 ohm load (±10%)
- Output Voltage 40 V peak to peak at 500 ohm load (±10%)
- Waveform True sine wave
- Pulse Width 100 µS fixed
- Pulse Rate Channels 1 & 3 fixed at 5000 Hz; Channels 2 & 4 variable 5001 - 5250 Hz
- LOW [Default IFT mode] Pulse Rate sweeps from 1 - 10 Hz per second
- HIGH Pulse Rate sweeps from 80 - 150 Hz per second
- WIDE Pulse Rate sweeps from 1 - 250 Hz per second
- FIXED w/ Vector Sweep Selectable fixed Pulse Rate from 10-200 Hz in 10 Hz increments. Built-in Vector Sweep provides a “sweeping” effect of the stimulation from Channel 1 to Channel 2 from 100% - 0% stimulation and then from 0% - 100% stimulation in a period of 22 seconds
- Amplitude 90 mA peak at 500 ohm load (±10%)
- Output Voltage 45 V peak to peak at 500 ophm load (±10%)
- Waveform Symmetrical biphasic
- Modes:
Conventional TNS [Default TENS mode] Pulse Width: Adjustable 50 - 250 µS [Default 250 ms]; Pulse Rate: Adjustable 1 - 150 Hz [Default 70 Hz]
Burst TNS Pulse Width: 250 µS fixed; Pulse Rate: 50 Hz with bursts of 7 pulses per second followed by 2-second rest
- Modulation TNS Pulse Width: Modulates between 100 - 200 µS over a 2 second time period; Pulse Rate: Adjustable 1 - 150 Hz [Default 150 Hz]
|
|