![Electrotherapy Overview](http://www.medi-stim.com/button/btn_overview.gif) ![Devices](http://www.medi-stim.com/button/btn_devices.gif) ![Electrodes](http://www.medi-stim.com/button/btn_electrodes.gif) ![Conductive Garments](http://www.medi-stim.com/button/conductive-garment.gif) ![Cables & Leadwires](http://www.medi-stim.com/button/btn_leadwires.gif)
![Skin Care](http://www.medi-stim.com/button/btn_skincare.gif)
![Batteries](http://www.medi-stim.com/button/btn_batteries.gif)
![Hot & Cold Therapy](http://www.medi-stim.com/button/btn_hotcold.gif) ![](http://www.medi-stim.com/button/btn-LSOorthopedicsppt) ![](http://www.medi-stim.com/button/btn_tractionunits.gif)
![Accessories](http://www.medi-stim.com/button/btn_accessories.gif)
Medi-Stim, Inc.
217 Industrial Court
Wabasha, MN 55981
Toll Free: 1-800-363-STIM
Ph: (651) 565-2400
Fax: (651) 565-2410
sales@medi-stim.com
|
NMES Units > EMS 7500 |
![](http://www.medi-stim.com/images/quoteMe_img.jpg)
|
EMS 7500
|
- Dual channel (4-lead) digital muscle stim
- 3 treatment modes (Alternating, Synchronous, or Constant)
- Adjustable rate & width, contraction/relaxation times, and ramp up/down
- Clear protective cap for intensity dials
- Treatment timer & compliance monitor
- Last setting recall
- Low battery indicator
- Three-year warranty
- Comes with 1 pkg of 4 reusable self-adhering electrodes, 1 set 43” pin lead wires, 1 each 9V heavy duty battery, carrying case, and instruction manual
- Leadwire reorder # LW46SPLE
- Channel: Dual, isolated between channels
Amplitude: Adjustable, 0 - 100 mA peak into 500 ohm load each channel
- Output Voltage: 0 - 50 V across 500 ohm load
- Waveform: Asymmetrical bi-phasic square pulse
- Pulse Rate: Adjustable, 2 - 150 Hz, 1 Hz/step
- Pulse Width: Adjustable, 50 - 300 microseconds, 10 µS/step
- Modes: Constant ,Synchronous, Alternate
Constant stimulation based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. “Constant” is equal to the “Normal” mode of a TENS unit.
Synchronous Stimulation of both channels occurs synchronously. The “ON” time including “Ramp Up” and “Ramp Down” time. Therefore, the setting of ON Time should be no less than two times of the “Ramp” time in this mode. ON TIME ≥ Ramp up + Ramp down
Alternate The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the “Ramp” time. The OFF Time should be equal or more than the ON Time. ON TIME ≥ Ramp up + Ramp down. OFF TIME ≥ ON TIME
- Patient Compliance Meter: This unit can store 60 sets of operation records. Total recorded time is 999 hours
- Timer: Adjustable, 5 - 60 minutes or Continuous. Adjustable in 5 minutes each step. Treatment time countdown automatically.
- Contraction Time: Adjustable, 2 ~ 90 seconds , 1 Sec/step
- Relaxation Time: Adjustable, 2 ~ 90 seconds , 1 Sec/step
- Ramp Time: Adjustable, 1 ~ 8 seconds, 1 Sec/step, The “On” time will increase and decrease in the setting value
- Power Supply: One 9-volt battery
- Size: 10.1 x 6.1 x 2.45 cm
- Weight:150 grams including battery
|
|