Toll Free: 1-800-363-STIM
Ph: (651) 565-2400
Fax: (651) 565-2410
sales@medi-stim.com
|
Interferential Units > QuadStar II |
|
QuadStar II
TENS/EMS/IF Unit |
- Four channel (8-lead) all digital combo TENS, Muscle Stim, and Interferential with sequential feature
- 3 Waveforms: Symmetrical, Asymmetrical biphasic, Pulsed Sine
- 4 Interferential modes, 3 TENS modes, 3 EMS modes
- Separate intensity controls for each channel
- Preset treatment programs
- Fully adjustable parameter settings for all modes
- Great choice for professional or clinical use
- AC adapter or 4 AA battery power supply
- Last setting recall and parameter lock
- Compliance monitor
- Treatment timer
- 3 year warranty
- Comes with 2 pkgs of 4 each 1.5” x 2.5” reusable self-adhesive electrodes, 4 each color-coded 48” pin lead wires, 4 each AA Alkaline Batteries, AC adapter, carrying case, and instruction manual
- Leadwire reorder #LW00013B, #LW00013G, #LW00013T, #LW00013W
- Channels: 4 Channel (8 lead)
- Power Supply: AC Adapter or 4 AA Alkaline Batteries
- Size: 6.30" x 2.75" x 1.25" (160mm x 70mm x 32mm)
- Weight: 11.4 oz. (323 grams)
- Amplitude: 0 - 98 mA peak to peak
- Output Voltage: 0 - 33 V peak to peak (Adjustable)
- Waveform: Pulsed Sine
- CH1/CH3 (Carrier) Frequency: 4000 Hz
- CH2/CH4 Frequency: 4001 - 4150 Hz (Adjustable)
- Beat Frequency: 1 - 150 Hz
• CH1/CH2 are an Interferential Pair
• CH1: Fixed Frequency (4000 Hz)
• CH2: Adjustable 4001 - 4150 Hz
• CH3/CH4 are an Interferential Pair
• CH3: Fixed Frequency (4000 Hz)
• CH4: Adjustable 4001 - 4150 Hz
- Premodulated INF (using one channel):A mixed interferential beat frequency will be produced only out of CH 1 and/or CH 3.
- Modes: Constant, Sweep 1, Sweep 2, Sweep 3
• Constant: Beat Frequency is adjustable from 1-150Hz
• Sweep 1: Beat Frequency modulates from 1 - 10 Hz and back over 12 seconds (6 second increase, 6 second decrease)
• Sweep 2: Beat Frequency modulates from 80 - 150 Hz and back over 16 seconds (8 second increase, 8 second decrease)
• Sweep 3: Beat Frequency modulates from 1 - 150 Hz and back over 20 seconds (10 second increase, 10 second decrease)
- Amplitude: 0 - 100 mA peak to peak
- Output Voltage: 0 - 50 V peak to peak
- Waveform: Biphasic square
- Pulse Rate: Adjustable 1 - 120 Hz
- Pulse Width: Adjustable 10 - 250 µS
- Modes: Constant, Burst, Modulation
• Constant: Pulse Rate (Hz) is adjustable from 1 - 120 Hz and Pulse Width (µS) is adjustable from 10 - 250 µS.
• Burst: 8 pulses per burst, 2 bursts per second. Pulse Width (µS) is adjustable from 10 - 250 µS.
• Modulation: Pulse Rate (Hz) is adjustable from 1-120 Hz and Pulse Width (µS) is adjustable from 10 - 250 µS and decreases 50% and back to set value over a 10 second cycle.
- Amplitude: 0 - 120 mA from peak to peak (adjustable)
- Output Voltage: 0 - 60 V from peak to peak (adjustable)
- Waveform: Symmetrical & Asymmetrical Biphasic Square
- Pulse Rate: Adjustable 1 - 120 Hz peak to peak
- Pulse Width: Adjustable 50 - 400 µS
- On Ramp: 0-10 seconds
- On Time: 0-99 seconds
- Off Ramp: 0-10 seconds
- Off Time: 0-99 seconds
- Modes: Constant, Cycled, Reciprocating
• Constant: Use the Constant Mode or a Pulse Rate greater than 60 Hz. for the relaxation of muscle spasms only. Use of continuous stimulation and/or rates above the normal physiological range (e.g., greater than 60 Hz) could lead to rapid onset of muscle fatigue, making the device less effective in producing repeated forceful muscle contractions.
• Cycled
• Reciprocating
|
|
|
|