QuadStar Elite
TENS/IF/EMS/High Volt Unit |
- Four channel (8-lead) all digital combo Interferential, Muscle Stim, TENS, and High Volt Pulsed Galvanic, with sequential feature
- 2 Active and 1 Dispersive channels for High Volt
- 4 waveforms (asymmetrical and symmetrical biphasic squarewave, sinewave, and twin-peak monophasic)
- 4 Interferential modes, 8 TENS modes, 3 EMS modes, 3 High Volt modes
- Separate intensity controls for each channel
- Programmable sequencing of different modalities
- Preset treatment programs
- Fully adjustable parameter settings for all modes
- Great choice for professional or clinical use
- AC adapter / DC charger with internal Ni-Cad battery pack supply
- Last setting recall and parameter lock
- Compliance monitor
- Treatment timer
- 3 year warranty
- Comes with 3 pkgs of 4 each 2” x 2” reusable self-adhesive electrodes, 1 pkg of 4” x 7” dispersive electrode, 4 each color-coded 48” pin lead wires for TENS/EMS/IF, 2 each 48” red single active pin lead wires, 1 each 48” black dispersive pin lead wire, AC adapter /DC charger, carrying case, and instruction manual
- Leadwire reorder #LW00013W, #LW00013B, #LW00013G, #LW00013T
- Channel (4) for INF, NMS, and TENS. (2) Active (red) and (1) Dispersive (black) for High Voltage
Electrodes/Leadwires (4) Leadwires - Style L00013MC (2) GV0014R (red single wires) and (1) GV0014B (black single wire)
- Power Supply internal battery P/N QSE 601 NiCad battery pack; External Specified Power Supply: P/N L60071 medical grade power supply
- Size 14.1 x 13.4 x 4.15 cm
- Weight 574 grams
- Amplitude 0 - 78 mA peak to peak
- Output Voltage 0 - 39 V peak to peak
- Waveform Continuous sinusoidal
CH1/CH3 (Carrier) Frequency 4000 Hz
CH2/CH4 Frequency 4001 - 4150 Hz adjustable
Beat Frequency 1 - 150 Hz
• CH1/CH2 are an Interferential Pair
• CH1: Fixed Frequency (4000 Hz)
• CH2: Adjustable 4001 - 4150 Hz
• CH3/CH4 are an Interferential Pair
• CH3: Fixed Frequency (4000 Hz)
• CH4: Adjustable 4001 - 4150 Hz
- Premodulated INF (using one channel) A mixed interferential beat frequency will be produced only out of CH 1 and/or CH 3.
Modes
- Constant Beat Frequency is adjustable from 1 - 150 Hz
- Sweep 1 Beat Frequency modulates from 1 - 10 Hz and back over 12 seconds (6 second increase, 6 second decrease)
- Sweep 2 Beat Frequency modulates from 80 - 150 Hz and back over 16 seconds (8 second increase, 8 second decrease)
- Sweep 3 Beat Frequency modulates from 1 - 150 Hz and back over 20 seconds(10 second increase, 10 second decrease)
- Amplitude 0 - 100 mA peak to peak
- Output Voltage 0 - 50 V peak to peak
- Waveform Asymmetrical biphasic square
- Pulse Rate Adjustable 1 - 120 Hz
- Pulse Width Adjustable 10 - 250 µS
- Modes Constant, Pulse Width Modulation, Pulse
- Rate Modulation, Rate & Width Modulation, SD1, SD2, Cycled Burst, Cycled Burst 2
- Constant - Pulse Rate (Hz) is adjustable from 1 - 120 Hz and Pulse Width (µS) is adjustable from 10 - 250 µS.
- Pulse Width Modulation - Decrease/Increase of set width 50% over 5 second cycle.
- Pulse Rate Modulation - Decrease/Increase of set width 50% over 5 second cycle.
- Pulse Width & Pulse Rate Modulation - Pulse Rate and Pulse Width alternately decrease and increase 50% of their set values over 5 seconds cycle.
- Strength Duration 1 - Increase of set Pulse Width 40%, decrease of set Pulse Rate 45% and decrease of Amplitude 10% over a 3 second period. Values return to original settings over the next 3 second period.
- Strength Duration 2 - Increase of a set Pulse Width 60% decrease of set Pulse Rate 90% and decrease of set Amplitude 13% over a 6 second period. Values return to original setting over the next 6 seconds.
- Cycled Burst (B1) - 2.5 seconds on, 2.5 seconds off. Adjustable Pulse Rate 1-200 Hz. Adjustable Pulse Width from 10 - 250 μS.
- Cycled Burst II (B2) - 8 pulses per 0.25 seconds, off for 0.25 seconds. Adjustable Pulse Width from 10 - 250 μS.
- Channel 2 active outputs; 1 dispersive return
- Amplitude 0 - 700 mA peak, adjustable
- Output Voltage 0 - 350 V adjustable
Waveform Pulsed galvanic twin peak monophasic delivered in pairs
- Pulse Rate 1 - 120 Hz, adjustable
- Pulse Width Inter pulse intervals of 100 (μS), fixed
Modes Constant Stimulation, Alternating Stimulation, Cycled Stimulation
- Polarity Switch Positive/Negative polarity of active electrodes (A1 & A2)
- Contraction Time 0 - 99 seconds
- Relaxation Time 0 - 99 seconds
- Ramp Up/Down 0 - 10 seconds
- Amplitude 0 - 120 mA from peak to peak (adjustable)
- Output Voltage 0 - 60 V from peak to peak (adjustable)
- Waveform Symmetrical, biphasic, square
- Asymmetrical, biphasic, square
- Pulse Rate Adjustable 1 - 120 Hz peak to peak
- Pulse Width Adjustable 50 - 400 µS
- Constant - Use the Constant Mode or a Pulse Rate greater than 60 Hz. for the relaxation of muscle spasms only. Use of continuous stimulation and/or rates above the normal physiological range (e.g., greater than 60 Hz) could lead to rapid onset of muscle fatigue, making the device less effective in producing repeated forceful muscle contractions.
- Cycled
- Reciprocating
- Ramp Up/Down 0 - 10 seconds
- Contraction Time 0 - 99 seconds
- Relaxation Time 0 - 99 seconds
|
|